• Zum Seiteninhalt (Accesskey 1)
  • Zur Hauptnavigation (Accesskey 2)
  • Bundesministerium Frauen, Wissenschaft und Forschung
  • Forschungsinfrastruktur-Datenbank
  • Start
  • Search
  • Mapping
    • Statistics by region
    • Cluster
    • Monitoring
    • Gallery
  • About
    • R&D - Institutions
    • Federal Ministry of Women, Science and Research (BMFWF)
    • Austrian Federal Economic Chamber (WKÖ)
    • Federal Ministry of Economy, Energy and Tourism (BMWET)
  • FAQs & Info
    • FAQs
      • Description of the Research Infrastructure
      • Methods & Services for Research Infrastructure
      • Research infrastructure categories
      • Additional Information to research Infrastructure
      • Search Engine
      • Contact
    • Information
      • National Strategy of Research Infrastructure
      • Research infrastructures in the European Union
      • Research infrastructure databases / Research infrastructure networks
      • BMBWF Research Infrastructure Database: Evaluation Study 2022
      • Awards and press releases
  • Registrieren
  • Login
  • DE
  • EN
Large equipment

Spektrometer "12T solariX XR FTMS" Komplettsystem

  • To Overview
  • »
  • 1523 / 2639
  • »

University of Innsbruck

Innsbruck | Website

Open for Collaboration

Short Description

The "12T solariX XR FTMS" is a high-end Fourier transform - ion cyclotron resonance (FT-ICR) instrument with a 12 Tesla superconducting magnet for the structural characterization of biomolecules including ribonucleic acids (RNA), proteins, and their complexes by top-down mass spectrometry (MS). The instrument offers high mass resolving power (≥ 500,000 for 1 second transients, > 10,000,000 maximum resolving power, both at m/z 400) and high mass accuracy (< 300 ppb average error with internal calibration, < 800 ppb average error with external calibration, both in the m/z range 100 - 1500). For smaller molecules (<1000 Da), the high mass resolving power allows for separation of 13C, 15N, 18O, and 34S isotopic peaks (isotopic fine structure).

The instrument is equipped with an electrospray ionization (ESI) source that can be operated in positive or negative ion mode, a collision cell for collisionally activated dissociation (CAD), and an indirectly heated cathode for electron capture dissociation (ECD), electron detachment dissociation (EDD), or electron induced dissociation (EID) experiments.

Contact Person

Kathrin Breuker

Research Services

The research infrastructure is “Open for Collaboration”. Commercial collaborations are not possible.

Methods & Expertise for Research Infrastructure

top-down mass spectrometry (MS), isotopic fine structure, collisionally activated dissociation (CAD), electron capture dissociation (ECD), electron detachment dissociation (EDD), electron induced dissociation (EID)

Terms of Use

The terms of use will be defined in the context of a scientific cooperation.
Terms of use are defined within the framework of scientific cooperation. No commercial use possible. If you are interested in a cooperation or collaboration, please contact us.

Reference Publications

https://www.uibk.ac.at/organic/breuker/

Contact

Kathrin Breuker
Institut für Organische Chemie
kathrin.breuker@uibk.ac.at
https://www.uibk.ac.at/organic/breuker/