• Zum Seiteninhalt (Accesskey 1)
  • Zur Hauptnavigation (Accesskey 2)
  • Bundesministerium Frauen, Wissenschaft und Forschung
  • Forschungsinfrastruktur-Datenbank
  • Start
  • Search
  • Mapping
    • Statistics by region
    • Cluster
    • Monitoring
    • Gallery
  • About
    • R&D - Institutions
    • Federal Ministry of Women, Science and Research (BMFWF)
    • Austrian Federal Economic Chamber (WKÖ)
    • Federal Ministry of Economy, Energy and Tourism (BMWET)
  • FAQs & Info
    • FAQs
      • Description of the Research Infrastructure
      • Methods & Services for Research Infrastructure
      • Research infrastructure categories
      • Additional Information to research Infrastructure
      • Search Engine
      • Contact
    • Information
      • National Strategy of Research Infrastructure
      • Research infrastructures in the European Union
      • Research infrastructure databases / Research infrastructure networks
      • BMBWF Research Infrastructure Database: Evaluation Study 2022
      • Awards and press releases
  • Registrieren
  • Login
  • DE
  • EN
Large equipment

WATERS Xevo TQ-XS - Mass spectrometer

  • To Overview
  • »
  • 23 / 2640
  • »

University of Salzburg

Salzburg | Website

Open for Collaboration

Short Description

Xevo TQ-XS: The requirements of a tandem quadrupole – mass spectrometer in the field of forensic toxicology are high robustness compared to matrix loads due to the study of various bodily fluids, as well as low Detection limits of possible drugs, toxins or other non-body-foreign substances. In particular, sensitivity is needed in the context of ' targeted analysis ' to certain drugs, pharmaceuticals, narcotics and antidepressants, among others.

The Xevo TQ – XS – LC-MS/MS system meets these challenges in addition to the classic functions of a tandem quadrupole with respect to various different scanning – modes:
-Multiple Reaction Monitoring (MRM)
Selected Ion Recording (SIR)
-Neutral Loss Scan (NL Scan)
-Product Ion Scan
-Precursor Ion Scan
-Simultaneous Full Scan and MRM (RADAR)
with a number of other technical innovations such as:
• StepWave XS™ ion transfer optics that provides increased sensitivity to demanding organic compounds.
• A detection system with a linear range above 6 sizes to ensure that the required sensitivity and quantification is achieved over a wide range of concentrations.
• A new user-friendly ion source that shortens the duration of maintenance and also provides stable reproducibility.

Contact Person

Prof. Dr. Thomas Keller

Research Services

forensic toxicology

Methods & Expertise for Research Infrastructure

Reproducible quantification with maximum sensitivity
The Xevo TQ – XS LC-MS/MS system is capable of analyzing both small and large molecules, individual analytes or multiple connecting groups of organic molecules up to 2000 Da. By the use of different sources of ionization, a wide range of analytical dindaries can be covered. Through other different technical innovations, such as the StepWave XS ion transfer optics, the system delivers maximum sensitivity advantages that can be reproduced even with multiple injections and make a reliable quantification even at the lowest level possible. The StepWave XS ensures that neutral connections and gas loads are passively removed to achieve better ion transfer. In the process, the ions are actively transferred to the mass analyzer, which improves sensitivity and robustness.

Xtended Dynamic Range Detector
The Xtended Dynamic Range (XDR™) detector now allows for a linear calibration range over 6 orders of magnitude. Thus, a larger concentration area can be covered without reaching the detector saturation to avoid time-consuming re-– injections as part of further dilutions of the sample.

Source optimization and maintenance without additional tools
No tools are required to replace the ion source. This leads to improved reproducibility over long periods of time.
"IntelliStart" provides a calibration – and tuning routine, which can be used at the beginning or within the sequence as required, provides a regular review of the system.
The software is rounded off by the integrated QUANPEDIA – method database for the creation and import of analytical methods

Allocation to research infrastructure

Forensische Toxikologie

Terms of Use

Please contact us via science.plus@plus.ac.at, or contact the responsible person for this section, mentioned in the contact field

Cooperation Partners

MVZ Labor Dessau

Contact

Prof. Dr. Thomas Keller
Fachbereich für Gerichtsmedizin und Forensische Psychiatrie
0043 662 8044 3805
thomas.keller@plus.ac.at
https://www.plus.ac.at/gerichtsmedizin-forensische-neuropsychiatrie/der-fachbereich/gerichtsmedizin/

Location

Location on map

Share this entry

  • Facebook
  • X.com
  • Pinterest
  • LinkedIn
  • E-Mail
© 2025 FEDERAL MINISTRY of WOMEN, SCIENCE and RESEARCH
  • Terms of use / General Data Protection Regulation
  • Declaration on accessibility
  • Imprint
  • Data protection settings