• Zum Seiteninhalt (Accesskey 1)
  • Zur Hauptnavigation (Accesskey 2)
  • Bundesministerium Frauen, Wissenschaft und Forschung
  • Forschungsinfrastruktur-Datenbank
  • Start
  • Search
  • Mapping
    • Statistics by region
    • Cluster
    • Monitoring
    • Gallery
  • About
    • R&D - Institutions
    • Federal Ministry of Women, Science and Research (BMFWF)
    • Austrian Federal Economic Chamber (WKÖ)
    • Federal Ministry of Economy, Energy and Tourism (BMWET)
  • FAQs & Info
    • FAQs
      • Description of the Research Infrastructure
      • Methods & Services for Research Infrastructure
      • Research infrastructure categories
      • Additional Information to research Infrastructure
      • Search Engine
      • Contact
    • Information
      • National Strategy of Research Infrastructure
      • Research infrastructures in the European Union
      • Research infrastructure databases / Research infrastructure networks
      • BMBWF Research Infrastructure Database: Evaluation Study 2022
      • Awards and press releases
  • Registrieren
  • Login
  • DE
  • EN
Large equipment

Single Crystal Diffractomter (Gwaihir) - X-ray center

  • To Overview
  • »
  • 73 / 190
  • »

Technical University of Vienna

Wien | Website

Open for Collaboration

Short Description

The single crystal diffractometer is a STOE-STADI VARI goniometer system with an open Eulerian cradle with angular ranges in 2Theta = 240°, omega = 205°, chi = 90° and phi = 360°. The instrument provides a position accuracy < 0.001° and a radius of the “Sphere of Confusion” less than 5 microns, which is especially useful working with small beam sizes. The open Eularian cradle supports loads of up to 2 kg on the phi axis. Therefore, heavy load sample environments can be adapted on the instrument.

The instrument is equipped with a Mo and Cu Micro-focus X-ray source (focus size: ~70µm (Mo), ~190µm (Cu)) together with a high-grade X-ray multi-layer optics for monochromatization. The switching between the two sources is software supported. The Eiger CdTe (1M) detctor allows also measurements of very weak scatterer.

Sample environment: Oxford Cryostream (T: 100K - 400 K); Heatstream (T: 300K - 1000K)

Contact Person

Dr. Berthold Stöger

Research Services

The research infrastructure is mainly used by TU Wien. For contract measurements/cooperations please contact us (https://www.tuwien.at/en/research/facilities/xrc/requests).

Methods & Expertise for Research Infrastructure

Structure elucidation of weakly scattering crystals
Structure elucidation of complex structures (modulated, twinned)
Diffuse scattering

Terms of Use

https://www.tuwien.at/en/research/facilities/xrc/requests

Cooperation Partners

Faculty technical physics, TU Wien
(single crystal measurements)

Faculty technical chemistry, TU Wien
(single crystal measurements)

Contact

Dr. Berthold Stöger
Röntgenzentrum/X-ray Center
+43 1 58801 406628
berthold.stoeger@tuwien.ac.at
https://www.tuwien.at/forschung/facilities/xrc/team

Location

Location on map

Share this entry

  • Facebook
  • X.com
  • Pinterest
  • LinkedIn
  • E-Mail
© 2025 FEDERAL MINISTRY of WOMEN, SCIENCE and RESEARCH
  • Terms of use / General Data Protection Regulation
  • Declaration on accessibility
  • Imprint
  • Data protection settings