• Zum Seiteninhalt (Accesskey 1)
  • Zur Hauptnavigation (Accesskey 2)
  • Bundesministerium Frauen, Wissenschaft und Forschung
  • Forschungsinfrastruktur-Datenbank
  • Start
  • Search
  • Mapping
    • Statistics by region
    • Cluster
    • Monitoring
    • Gallery
  • About
    • R&D - Institutions
    • Federal Ministry of Women, Science and Research (BMFWF)
    • Austrian Federal Economic Chamber (WKÖ)
    • Federal Ministry of Economy, Energy and Tourism (BMWET)
  • FAQs & Info
    • FAQs
      • Description of the Research Infrastructure
      • Methods & Services for Research Infrastructure
      • Research infrastructure categories
      • Additional Information to research Infrastructure
      • Search Engine
      • Contact
    • Information
      • National Strategy of Research Infrastructure
      • Research infrastructures in the European Union
      • Research infrastructure databases / Research infrastructure networks
      • BMBWF Research Infrastructure Database: Evaluation Study 2022
      • Awards and press releases
  • Registrieren
  • Login
  • DE
  • EN
Large equipment

Rapiflex MALDI

  • To Overview
  • »
  • 1023 / 2648
  • »

Medical University of Vienna

Wien | Website

Open for Collaboration

Short Description

The rapifleX MALDI mass spectrometer is a high resolution time-of-flight mass spectrometer that enables fast and reliable analysis and imaging of lipids, proteins and peptides from biological samples. Furthermore, Rapiflex can be used for detecting and analyzing binding sites of active substances in tissue by applying the imaging approach.
The instrument can acquire up to 40 true pixels/second and deliver faster and better images as compared to other MALDI-ToF instruments. A smartbeam™ 3D laser is used for improved pixel-to-pixel reproducibility and the ion source design enables for increased robustness an less background in mass spectra.
The instrument enables high data acquisition speeds, and the very important high spatial resolution capabilities for clear imaging with high mass resolving power.
Another important technical detail is the use of the smartbeam™ 3D laser. This laser features a diameter of 5µm. and it can move independently from the sample stage. Therefore, it is possible to scan the full area of each pixel and generate truly square pixels, which utilizes the complete available sample area and results with maximum sensitivity and excellent pixel-to-pixel reproducibility.

Contact Person

Goran Mitulović

Research Services

MALDI analysis and identification of lipids, peptides, and proteins. MALDI Imaging of tissue samples.

Methods & Expertise for Research Infrastructure

The Proteomics Core Facilities provides expertise in sample preparation and analysis for both classical MALDI and MALDi Imaging analysis.

Allocation to research infrastructure

Core Facility Proteomics

Terms of Use

Please contact the Proteomics Core Facility for project planning.

Contact

Goran Mitulović ist der Leiter der Proteomics Core Facility und Verantwortlicher für die Geräte in der Core Facility.
Goran Mitulović
Proteomics Core Facility
014040053750
goran.mitulovic@meduniwien.ac.at
http://www.meduniwien.ac.at/cf-proteomics

Location

Location on map

Share this entry

  • Facebook
  • X.com
  • Pinterest
  • LinkedIn
  • E-Mail
© 2025 FEDERAL MINISTRY of WOMEN, SCIENCE and RESEARCH
  • Terms of use / General Data Protection Regulation
  • Declaration on accessibility
  • Imprint
  • Data protection settings